Generac Guardian
Generac Guardian offers the following generator types: home standby, portable and recreational vehicle.
Generac Guardian
http://www.guardiangenerators.com/
Corporate Mailing Address:
Generac Power Systems
Hwy. 59 & Hillside Road
P.O. Box 8
Waukesha, WI 53187
Guardian consumer products from Generac Power Systems are renowned for value, reliability, and long life. These versatile and durable power generation products serve a wide variety of residential, commercial, small business, and recreational vehicle applications.
Generac Gaurdian offers generators according to the following categories:
Home standby, portable and recreational vehicle.
HOME STANDBY PRODUCTS
Guardian 7, 12 & 15 kW
Generator Set |
|
| Model Number |
04389 |
04456 |
04390 |
Rated Power LP (kW) |
7 |
12 |
15** |
| Rated Power NG (kW) |
6 |
12 |
13 |
Voltage @ 60 Hz |
120/240 |
120/240 |
120/240 |
| Phase |
Single |
Single |
Single |
Frequency |
60 Hz |
60 Hz |
60 Hz |
Amps LP |
58.3/29.2 |
100.0/50.0 |
125.0/62.5 |
| Amps NG |
50.0/25.0 |
100.0/50.0 |
108.3/54.2 |
Engine/Alternator RPM |
3600/3600 |
3600/3600 |
3600/3600 |
| Engine |
410 cc.
14.5 HP
Generac OHVI
Single Cylinder |
992 cc.
30 HP
Generac OHVI
V-Twin |
992 cc.
30 HP
Generac OHVI
V-Twin |
EPA/CARB Certified |
Yes |
Yes |
Yes |
| Fuel |
Natural Gas/
LP Vapor |
Natural Gas/
LP Vapor |
Natural Gas/
LP Vapor |
Engine Cooling |
Air |
Air |
Air |
| UL2200 |
Yes |
Yes |
Yes |
| Canadian UL |
Yes |
Yes |
Yes |
| Main Line Circuit Breaker |
40 Amp |
50 Amp |
60 Amp |
Dimensions (L" x W" x H") |
48 x 24 x 28-1/4 |
48 x 24 x 28-1/4 |
48 x 24 x 28-1/4 |
| Unit Wt. (lbs.) |
452 |
470 |
487 |
Controls |
|
| Start/Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection. |
| Automatic Low Oil Shutdown |
Standard |
| Overspeed Shutdown |
Standard, 72 Hz |
| Overcrank Protection |
Standard |
| Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
| Engine Warmup |
10 seconds |
| Engine Cool-Down |
1 minute |
| Safety Fuse |
Standard |
| Starter Lockout |
Starter cannot re-engage until 5 seconds after the engine has stopped |
| 2 Amp Timed Trickle Battery Charger |
Standard |
| Auto Switch |
Utility failure/7 day exercise |
| Off Switch |
Stops unit. Power is removed. Control and charger still operate |
| Manual / test |
Start with starter control, unit stays on. If utility fails, transfer to load takes place |
Transfer Switch |
|
| No. of Poles |
2 |
| Current Rating (amps) |
100 |
| Voltage Rating (VAC) |
250 |
Utility Voltage Monitor (fixed)
Pick-up
Drop out |
70%
60% |
| Return to Utility |
Approx. 13 seconds |
| Exercises 7 minutes weekly |
Standard |
| UL Listed |
Standard |
| Dimensions (H" x W" x D") |
26.5 x 12.5 x 7 |
Guardian 15 & 20 kW
Generator Set |
|
| Model |
04721 |
04723 |
Rated Power (kW)* |
15 |
20 |
| 60 Hz Phase |
Single |
Single |
Voltage |
120/240V |
120/240V |
| Amps @ 120/240V, Single Phase 60 Hz |
125/62.5 |
166.6/83.3 |
Engine / Alternator RPM |
1800 |
3600 |
| Engine |
="center">1.5L OHC 4 cyl. |
1.5L OHC 4 cyl. |
Fuel |
Natural gas or LP gas |
Natural gas or LP gas |
| UL 2200 Listed |
Yes |
Yes |
| CSA Listed |
Yes |
Yes |
| Main Line Circuit Breaker |
70 Amp |
90 Amp |
| Engine Cooling |
Liquid |
Liquid |
Dimensions (L" x W" x H") |
68 x 30 x 40 |
68 x 30 x 40 |
| Unit Wt. (lbs.)** |
980 |
985 |
* Natural gas and LP gas rating may decrease depending on btu content of local gas supply. Proper sizing of tank/piping is required to ensure full output.
** Includes Transfer Switch
Controls |
|
| Start / Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection. |
Automatic Low Oil Shutdown |
Standard |
| Overspeed Shutdown |
Standard, 70 Hz |
Overcrank Protection |
Standard |
| Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
Engine Warmup |
15 seconds |
| Engine Cool-Down |
1 minute |
Safety Fuse |
Standard |
| Starter Lockout |
Starter cannot re-engage until 5 seconds after engine has stopped |
2 Amp Timed Trickle Battery Charger |
Standard |
| Mode Switch: Auto Switch |
Utility failure/7 day exerciser |
Auto Switch |
Utility failure/7 day exercise |
| Off Switch |
Stops unit. Power is removed. Control and charger still operate |
Manual / Test |
Start with starter control, unit stays on. If utility fails, transfer to load takes place |
Guardian 25 kW
Generator Set |
| Model |
04725 |
Rated Power (kW)* |
25 |
| 60 Hz Phase |
Single |
Voltage |
120/240V |
| Amps @ 120/240V, Single Phase 60HZ |
208.3/104.2 |
Engine / Alternator RPM |
3600 |
| Engine |
1.5L OHC 4 cyl. |
Fuel |
Natural gas or LP gas |
| UL 2200 Listed |
Yes |
| CSA Listed |
Yes |
| Main Line Circuit Breaker |
125 Amp |
| Engine Cooling |
Liquid |
Dimensions (L" x W" x H") |
68 x 30 x 40 |
| Unit Wt. (lbs.)** |
1010 |
*Natural gas and LP gas rating may decrease depending on btu content of local gas supply. Proper sizing of tank/piping is required to ensure full output.
** Includes Transfer Switch
| Controls |
|
| Start / Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection. |
Automatic Low Oil Shutdown |
Standard |
| Overspeed Shutdown |
Standard, 70 Hz |
Overcrank Protection |
Standard |
| Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
Engine Warmup |
15 seconds |
| Engine Cool-Down |
1 minute |
Safety Fuse |
Standard |
| Starter Lockout |
Starter cannot re-engage until 5 seconds after engine has stopped |
2 Amp Timed Trickle Battery Charger |
Standard |
| Mode Switch: Auto Switch |
Utility failure/7 day exerciser |
Auto Switch |
Utility failure/7 day exercise |
| Off Switch |
Stops unit. Power is removed. Control and charger still operate |
Manual / Test |
Start with starter control, unit stays on. If utility fails, transfer to load takes place |
|
Guardian 30 kW
Generator Set |
|
| Model |
4988 |
Rated Power (kW)* |
LPG 30 / NG 27 |
| 60 Hz Phase |
Single |
Voltage |
120/240V |
| Amps @ 120/240V, Single Phase 60HZ |
250.3/125.0 |
Engine / Alternator RPM |
1800 |
| Engine |
3.0L L V-6 |
Fuel |
Natural gas or LP gas |
| UL 2200 Listed |
Yes |
| CSA Listed |
Yes |
| Main Line Circuit Breaker |
150 Amp |
| Engine Cooling |
Liquid |
Dimensions (L" x W" x H") |
76 x 33.5 x 42.2 |
| Unit Wt. (lbs.)** |
1350 |
* Natural gas and LP gas rating may decrease depending on btu content of local gas supply. Proper sizing of tank/piping is required to ensure full output.
** Includes Transfer Switch
Guardian 40 kW
|
Generator Set |
|
| Model |
04992 |
Rated Power (kW)* |
LP 40 / NG 37 |
| 60 Hz Phase |
Single |
Voltage |
120/240V |
| Amps @ 120/240V, Single Phase 60Hz |
LP 333.3 / 166.6
NG 308.3 / 154.2 |
Engine / Alternator RPM |
1800 |
| Engine |
3.9L V6 |
Fuel |
Natural gas or LP gas |
| UL 2200 Listed |
Yes |
| CSA Listed |
Yes |
| Main Line Circuit Breaker |
200 Amp |
Dimensions
(L" x W" x H") |
76.1 x 33.5 x 42.2 |
| Unit Wt. (lbs.)** |
1400 |
* Natural gas and LP gas rating may decrease depending on btu content of local gas supply. Proper sizing of tank/piping is required to ensure full output.
** Includes Transfer Switch
Controls |
|
| Start / Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection. |
Automatic Low Oil Shutdown |
Standard |
| Overspeed Shutdown |
Standard, 70 Hz |
Overcrank Protection |
Standard |
| Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
Engine Warmup |
15 seconds |
| Engine Cool-Down |
1 minute |
Safety Fuse |
Standard |
| Starter Lockout |
Starter cannot re-engage until 5 seconds after engine has stopped |
2 Amp Timed Trickle Battery Charger |
Standard |
Auto Switch |
Utility failure/7 day exercise |
Off Switch |
Stops unit. Power is removed. Control and charger still operate |
| Manual / Test |
Start with starter control, unit stays on. If utility fails, transfer to load takes place |
Guardian Elite 20 & 25 kW
| Model Number |
5210 |
5212 |
Rated Power LP (kW) |
20 |
25 |
| Rated Power NG (kW) |
20 |
25 |
Voltage @ 60 Hz |
120/240 |
120/240 |
| Phase |
Single |
Single |
Frequency |
60 Hz |
60 Hz |
Amps LP |
166.6/83.8 |
208.3/104.2 |
| Amps NG |
166.6/83.8 |
208.3/104.2 |
Engine/Alternator RPM |
3600/3600 |
1800/1800 |
| Engine |
1.5 Liter
In-line
4-cylinder |
2.5 Liter
In-line
4-cylinder |
EPA/CARB Certified |
Yes |
Yes |
| Fuel |
Natural Gas/
LP Gas |
Natural Gas/
LP Gas |
Engine Cooling |
Liquid |
Liquid |
| UL2200 Listed |
Yes |
Yes |
| CUL Listed |
Yes |
Yes |
| Main Line Circuit Breaker |
100 Amp |
125 Amp |
Dimensions (L" x W" x H") |
71 x 29.5 x 36 |
71 x 29.5 x 36 |
| Unit Wt. (lbs.) |
776 |
1045 |
|
| Specifications subject to change without notice. |
| Start/Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection. |
| Automatic Low Oil Shutdown |
Standard |
| Overspeed Shutdown |
Standard, 70 Hz |
| Overcrank Protection |
Standard |
| Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
| Engine Warmup |
10 seconds |
| Engine Cool-Down |
1 minute |
| Safety Fuse |
Standard |
| Starter Lockout |
Starter cannot re-engage until 5 seconds after the engine has stopped |
| 2 Amp Timed Trickle Battery Charger |
Standard |
| Auto Switch |
Utility failure/7 day exercise |
| Off Switch |
Stops unit. Power is removed. Control and charger still operate |
| Manual / test |
|
|
Guardian Elite 30 & 40 kW
Generator Set
| Model Number |
5219 |
5221 |
Rated Power LP (kW) |
30 |
40* |
| Rated Power NG (kW) |
27 |
37 |
Voltage @ 60 Hz |
120/240 |
120/240 |
| Phase |
Single |
Single |
Frequency |
60 Hz |
60 Hz |
Amps LP |
250/125 |
333.3/166.6 |
| Amps NG |
225/112.5 |
308.3/154.2 |
Engine/Alternator RPM |
1800/1800 |
1800/1800 |
| Engine |
3.0 Liter
V-6 |
3.9 Liter
V-6 |
EPA/CARB Certified |
Yes |
NO* |
| Fuel |
Natural Gas/
LP Gas |
Natural Gas/
LP Gas |
Engine Cooling |
Liquid |
Liquid |
| UL2200 Listed |
Yes |
Yes |
| CUL Listed |
Yes |
Yes |
| Main Line Circuit Breaker |
150 Amp |
175 Amp |
Dimensions (L" x W" x H") |
77 x 33.5 x 45 |
77 x 33.5 x 45 |
| Unit Wt. (lbs.) |
1431 |
1658 |
| Start/Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection. |
| Automatic Low Oil Shutdown |
Standard |
| Overspeed Shutdown |
Standard, 70 Hz |
| Overcrank Protection |
Standard |
| Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
| Engine Warmup |
10 seconds |
| Engine Cool-Down |
1 minute |
| Safety Fuse |
Standard |
| Starter Lockout |
Starter cannot re-engage until 5 seconds after the engine has stopped |
| 2 Amp Timed Trickle Battery Charger |
Standard |
| Auto Switch |
Utility failure/7 day exercise |
| Off Switch |
Stops unit. Power is removed. Control and charger still operate |
| Manual / test |
Start with starter control, unit stays on. If utility fails,transfer to load takes place |
|
PORTABLE GENERATORS
GUARDIAN Portable
Generator Model |
12500 |
15000 |
Model Number |
04451 |
04582 |
| Rated Watts |
12500 |
15000 |
Surge Watts |
18750 |
22500 |
| Voltage (Vac) |
120/240 |
120/240 |
Output (A) |
104/52 |
125/62.5 |
| Engine Type |
Generac V-Twin
OHVI 760cc
27 HP
Electric Start |
Generac V-Twin
OHVI 992cc
30 HP
Electric Start |
Weight |
417 |
450 |
Dimensions (H" x W" x L")
Fully assembled with handle and wheel kit |
38.5 x 30.75 x 48.5 |
38.5 x 30.75 x 48.5 |
Full Pressure Lubrication |
X |
X |
| Single Point Lifting |
X |
X |
Spin-on Oil Filter |
X |
X |
| Automotive 3-stage Air Filtration |
X |
X |
Automatic Idle Control |
X |
X |
| Lifetime Carbon Excitation Brushes |
X |
X |
Low Oil Pressure Shutdown |
X |
X |
| Automatic VoltageRegulation (AVR) |
X |
X |
Solid State Volt. Regulator |
X |
X |
| GFI Protection |
X |
X |
Anti-Vibration System |
X |
X |
| Circuit Breakers |
X |
X |
Battery Charge Cables |
X |
X |
| Maintenance Free Battery |
X |
X |
Full 1-1/4" Tubular Frame |
X |
X |
| Pneumatic Wheel Kit |
X |
X |
Electronic Governor |
X |
X |
| MSRP |
$2,475.00 |
$2,715.00 |
RECREATIONAL VEHICLE PRODUCTS
IMPACT® Series |
|
| Model |
36G plus II |
36LP plus II |
Model # |
00940 |
00941 |
Engine |
Generac OHVI |
Generac OHVI |
| # of Cylinders |
Single |
Single |
Engine RPM |
Variable |
Variable |
| Fuel |
Gasoline |
Propane |
Wattage |
3600 |
3400 |
| Weight LBS. |
97 |
99 |
| Dimensions L x W x H (in.) |
18.38 x 15.75 x 16.75 |
20.5 x 17.0 x 16.75 |
Average Fuel Consumption
No Load
1/2 Load
Full Load |
|
gal./hr.
0.14
0.32
0.54 |
gal./hr./cu.ft./hr.
0.20/0.84
0.41/1.72
0.77/3.25 |
Hertz |
60 |
60 |
| Phase |
Single |
Single |
Volts |
120 |
120 |
| Amps |
30.0 |
28.3 |
Typical Applications |
Truck Camper
Travel Trailer
Fifth Wheel |
Truck Camper
Travel Trailer
Fifth Wheel |
Primepact® Series |
| Model |
50G |
50LP |
| Model # |
02010 |
04164 |
| Engine |
Generac OHVI |
Generac OHVI |
| # of Cylinders |
Single |
Single |
| Engine RPM |
2570 |
2570 |
| Fuel |
Gasoline |
Propane |
| Wattage |
4800 |
4500 |
| Weight (lbs.) |
198 |
200 |
Dimensions L x W x H (in.) |
25.5 x 18.88 x
16.75 |
25.75 x 18.88 x
16.75 |
Average Fuel Consumption
No Load
1/2 Load
Full Load |
|
gal./hr.
0.32
0.46
0.76 |
gal./hr./cu.ft./hr.
0.47/1.97
0.72/3.06
1.25/5.32 |
| Hertz |
60 |
60 |
| Phase |
Single |
Single |
| Volts |
120 |
120 |
| Amps |
40 |
37.5 |
Typical Applications |
Class A
Class C
Travel Trailer |
Class A
Class C
Travel Trailer |
Quietpact® Series |
| Model |
40G |
55G |
55LP |
| Model # |
04700 |
04702 |
04703 |
| Engine |
Generac OHVI |
Generac OHVI |
Generac OHVI |
| # of Cylinders |
Single |
Two (V-Twin) |
Two (V-Twin) |
| Engine RPM |
3600 |
2200 |
2200 |
| Fuel |
Gasoline |
Gasoline |
LPG |
| Wattage |
3600 |
5500 |
5500 |
| Weight (lbs.) |
165 |
326 |
329 |
| Dimensions L x W x H (in.) |
29.5 x 19.0 x 13.5 |
33.7 x 22.2 x 19.6 |
33.7 x 22.2 x 19.6 |
Average Fuel Consumption
No Load
1/2 Load
Full Load |
|
(gal./hr.)
0.23
0.32
0.55 |
(gal./hr.)
0.51
0.73
0.97 |
(gal./hr.)/cu.ft./hr.
(0.55)/2.34
(0.93)/3.96
(1.20)/5.07 |
| Hertz |
60 |
60 |
60 |
| Phase |
Single |
Single |
Single |
| Volts |
120 |
120 |
120 |
| Amps |
30 |
45.8 |
45.8 |
| Typical Application |
Class C w/ 1 Air Conditioner
Travel Trailer
Van & Truck Camper |
Class A
Class C
Travel Trailer |
Class A
Class C
Travel Trailer |
| Model |
65G |
65LP |
75G |
| Model # |
04704 |
04705 |
04706 |
| Engine |
Generac OHVI |
Generac OHVI |
Generac OHVI |
| # of Cylinders |
Two (V-Twin) |
Two (V-Twin) |
Two (V-Twin) |
| Engine RPM |
2571 |
2571 |
2571 |
| Fuel |
Gasoline |
LPG |
Gasoline |
| Wattage |
6500 |
6500 |
7500 |
| Weight (lbs.) |
328 |
331 |
330 |
| Dimensions L x W x H (in.) |
33.7 x 22.2 x 19.6 |
33.7 x 22.2 x 19.6 |
33.7 x 22.2 x 19.6 |
Average Fuel Consumption
No Load
1/2 Load
Full Load |
|
(gal./hr.)
0.51
0.76
1.07 |
(gal./hr.)/cu.ft./hr.
(0.55)/2.34
(1.0)/4.20
(1.53)/6.50 |
(gal./hr.)
0.51
0.8
1.28 |
| Hertz |
60 |
60 |
60 |
| Phase |
Single |
Single |
Single |
| Volts |
120 |
120 |
120/240 |
| Amps |
54.2 |
54.2 |
62.5/31.2 |
Typical Application |
Class A
Fifth Wheel |
Class A
Fifth Wheel |
Class A
Fifth Wheel |
| Model |
75LP |
75D |
| Model # |
04707 |
04270 |
| Engine |
Generac OHVI |
Diesel |
| # of Cylinders |
Two (V-Twin) |
Three |
| Engine RPM |
2571 |
1950 |
| Fuel |
LPG |
Diesel |
| Wattage |
7500 |
7500 |
| Weight (lbs.) |
333 |
486 |
| Dimensions L x W x H (in.) |
33.7 x 22.2 x 19.6 |
36.6 x 23.8 x 22.3 |
Average Fuel Consumption
No Load
1/2 Load
Full Load |
|
(gal./hr.)/cu.ft./hr.
(0.55)/2.34
(1.05)/4.44
(2.06)/8.75 |
(gal./hr.)
0.31
0.57
0.74 |
| Hertz |
60 |
60 |
| Phase |
Single |
Single |
| Volts |
120/240 |
120/240 |
| Amps |
62.5/31.2 |
62.5/31.2 |
Typical Application |
Class A
Fifth Wheel |
Class A |
|
|
|
|
Generators
Onan Parts
McCulloch
Kubota
Hydrogen
Honda
Repair
Sitemap
Uncle Bobs Tips
| |